Sale!

Shear Design of Practical Column

0.00

Only Registered Users can Download this Product. If You not Registered or Logined. then

Login Now  or    Register/ Sign UP

Description

Loading

Name of File :-  Shear Design of Practical Column

Punching shear for walls on raft foundation:

  1. Usually walls are long elements and punching may not be critical. Only one-way shear checking may be sufficient.
  2. However, for small length walls, it may be checked at d/2 similar to columns.
  3. Shear design for columns: One example is attached here. Note that one face reinforcement is accounted for calculating c. Also, if Vu > Vuc, design as per beams.