Description
Name of File :- G.A. and Reinforcement Drawing for Pier Well and Well Cap for Yamuna P8 to P14 W2 RB 4161 F
Plan Feature :-
-
-
- Plan of Wall Cap.
- Reinforcement Detail of Wall Cap.
- Section A-A
- Section B-B
- Section C-C.
- Section D-D.
- Half Section <–> Half Elevation
- Section and Elevation of Pier Cap.
- Reinforcement Detail of Pier Wall.
- Reinforcement Detail of Cutting Edge-X.
-
Name of Project :- Dedicated Freight Corridor Corporation of India Ltd.
Legend
Top Face REINF,
Bottom Face REINF,
BOWC ——— Bottom of Well cap
FDNL ———- Foundation Level
LD———- Development Length
Length Varies — L.V.
Notes:-
- All Dimensions Are in Mm and Levels Are in M. Unless Otherwise Noted.
- Only Written Dimensions Are to Be Followed. Dimensions Are Not to Be Scaled,
- Grade of Concrete
For Well Cap, Staining & Curb – M35
For Bot Plug -m25 - ‘t’ Denotes H.Y,S.D, / TMT Bars (Grade Designation : Fe500) Conforming to Is: 1786 (Latest).
- Clear Cover to Any Reinforcement Shall Be 50mm, Unless Noted Otherwise.
- Laps Shall Be Staggered and Minimum Lap Length of Reinforcement Shall Be 600
- Minimum Anchorage Length of Reinforcement Shall Be 46 X Dia. of Bars Unless Noted Otherwise.
- This Drawing Will Superseded All the Previous Revisions Submitted So Far the Drawings of the Previous Revision/s Shall Be Destroyed and Removed From the Site.
- for Other Note Refer Separate Drawing.
Reviews